Combined and Separated Type Electromagnetic Flow Meter
Basic Info.
Model NO.:Electromagnetic Flow Meter
Accuracy:±0.5%
Main Application:Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size:Dn10-Dn1200
Sensor:Clamp-on/External
Application:Industrial Production
Type:Electromagnetic Flow Meter
Measuring Media:Liquid
Measuring Principle:Electrical Principles
.
Measurement Object:Closed Pipeline
Certification:JIS, DIN, ANS, GB, CE, UL, RoHS, SGS, ISO
Range Degree:150:1
Output:4~20mA,LCD Display
Operation Pressure:(0.6 1.0 1.6 4.0)MPa
Size.:Dn10-Dn1200
Power:220VAC, 50Hz, 24VDC
Export Markets:Global
Additional Info.
Trademark:Tianjin U-ideal Instrument
Packing:Wooden Case or Carton
Standard:CE, ROHS, SGS, GMP
.
Origin:Tianjin, China
HS Code:90261000
Production Capacity:50000PCS/Year
Product Description
Combined and Separated type Electromagnetic Flow Meter,Integrated and Separated type
Product Feature
1.No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.
2.Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.
3.On-site modification of the measuring range available.
4.LCD display, easy to use and simple to operate.
5.Using SMD devices and SMT technology.
6.Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.
7.Anti-interference, reliability, measurement range up to 150:1.
8.Ultra low EMI switch, wide range of power supply voltage.
9.RS485, RS232, Hart and Modbus digital communication signal output.
10.Self-checking function.
Wide application
chemical
power supply
metallurgical mine
oil
water supply and drainage
paper making
pharmaceutical
food and beverage
Specifications:
Item | Specifications |
Caliber(mm) | DN25~DN200 |
Pressure(MPa) | 1.0,1.6 |
Accuracy | ±0.5% |
Applicable medium | Conductive liquid and slurry |
Medium Temperature | ≤150°C |
Medium Conductivity | ≥5μS/cm |
Medium Velocity | ≤15 m/s |
Ambient | Temperature:-25°C~+60°C, Humidity: 5%~90% |
Liner Material | Rubber, PTFE, Hard rubber, etc. |
Electrode Material | SS316L,Ti,Ta,HB,HC,etc. |
Electrode Type | Fixed type |
Flange Material and standard | SS, CS Chinese national standard, ANSI standard, DIN, JSK, etc. |
Signal Output | 4-20mA; Pulse |
Display | LCD display with back light, able to display positive and negative instantaneous and accumulative flow |
Communication | RS485, Modbus, RS232, HART, Profibus-DP |
Power Supply | AC 85-265V, 45-63Hz, power≤20W; DC 11-40V; lithium battery(3.6V) |
Protection Grade | IP65(convertor), IP67/68(sensor) |
Explosion- proof Grade |
Exdm2CT4, md2BT4 |
Available Form | Compact/Remote |