Rotating Paddle Switch S10-Z for Bulk Solids
Basic Info.
Model NO.:S10-Z
Rotary Number:Single Button
Usage:Bulk Solid
Standard:Standard
Structure:Screw Shank
Operation:Automatic
Certification:ISO, GS
Switch Type:Spdt
.
Power Requirement:220VAC /110VAC/24VAC/24VDC
Electrical Rating:4W
Working Temperature:-10~80 Centigrade Max 400
Sensitivity:≥0.5g/cm3
Warranty Period:1year
Export Markets:Global
Condition:New
[button url="http://www.china-flow-meters.com/contact/" class="button" size="small" color="autumn" target="_self" lightbox_content="" lightbox_description=""] Inquiry now [/button]
Additional Info.
Trademark:Tianjin U-ideal Instrument
Packing:Wooden Cases or Carton
Standard:sgs, iso
.
Origin:Tianjin, China
HS Code:90261000
Production Capacity:300PCS/Month
Product Description
S10 is a rotary paddle switch for point level detection in bulk solids.
The paddle switch technology detects full, empty or demand conditions on materials such as grain, feed, cement, plastic granulate and wood chips.
It has outstanding features such as good sealing, strong overload capacity, lightweight and easy to installation, large output contacts capacity, etc. In view of the different proportion of material can be done by adjustable tension of the spring, contact material part of its full stainless steel material. Resistance rotary switch in the chemical, plastic, cement, medicine, feed, food and other industries widely used.
Working Principle
A low revolution geared motor with slip clutch drives a rotating measuring vane which senses the presence of material at the mounted level of the S10&S3. As material comes into contact with the rotating paddle, rotation stops, which changes the microswitch state. When the paddle is no longer covered by material, rotation resumes and the relay reverts to its normal condition.
Tension of the spring may be adjusted according to the proportion of the measured medium. Spring is adjusted to the strongest when material proportion get the max, on the contrary, it is adjusted to the weakest.
Products Features
1. American small hopper apparatus technology, three bearing support, more reliable operation.
2. The original seal design can prevent the dust into (patent) actual
3. The performance of torsion is stable and reliable..
4. If the rotary paddle bears an extra overload, the motor will be appeared slide to prevent the inside mechanism damaged.
5. It is rationally designed, the inside mechanisms are easily tore down for checking, maintenance and replacement. It doesn"t necessary to remove the complete set from the tank.
6. The junction box is IP65 protection grade, good sealing, and can be used outdoors
7. Special vane can be used in low density materials.
8. It can be used in wide range such as the iron and steel, cement, electric power, feed, chemical plastics, chemical fertilizer industry, etc
Selection Catalogue
Type | S10- (Special in the small hopper) | |
Connecting Shaft | C | Standard thread type installation |
F | Standard Flange type installation | |
Z | Shaft protection tube type | |
G | High temperature thread type | |
GF | High temperature Flange type | |
GZ | Shaft protection tube type | |
Vane shape | A | 85*35 |
B | 20*80 decomposable Blades | |
X | Double 85*35 Cross Blades | |
Vane shape: | 1 | 220VAC |
2 | 24VDC |
Installation notice
1. As shown in the above, the resistance switch should avoid installation and blanking under the falling medium , when it cannot be avoid, protective plate should be installed above the vane, in order to protect the vane.
2. To avoid outdoor rainwater into the terminal box, the input line should straight down in horizontal installation. Cable fixed nut must lock. It is better to install rain cover.
3. When installation hole size less than the width of vane, vane can be removed after the installation, before assembly, the thread should be smear with hypoxia glue, to prevent the leaf falls off in the process of operation.
4. Confirm the power supply voltage is the marked voltage
5. Confirm the installation way is horizontal or vertical.
6. When using a short type, opening size must be greater than 35 mm.