Magnetic Flow Meter for Beer, Liquid, Dairy

Sanitary Electromagnetic Magnetic Flow Meter for Beer, Liquid, Dairy

Sanitary Electromagnetic Magnetic Flow Meter for Beer, Liquid, Dairy

Basic Info.
Model NO.:Electro magnetic Flowmeter
Main Application:Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Certification:JIS, DIN, ANS, GB, CE, UL, RoHS, SGS, ISO
Process Connection:Ss304 Flange

.
Protection Class:IP65
Housing Material:Carbon Steel
Display:LCD
Power Supply:AC86-220V or DC24V
Export Markets:Global
Inquiry now

Additional Info.
Trademark:Tianjin U-ideal Instrument
Packing:Wooden Case or Carton
Standard:CE, ROHS, SGS, GMP

.
Origin:Tianjin, China
HS Code:90261000
Production Capacity:50000PCS/Year

Product Description
Electro magnetic Flowmeter,Sanitary Electromagnetic magnetic flow meter for Beer,liquid,dairy
Product Introduction
This  series electromagnetic flowmeters are made up of sensor and transducer, together with LCD screen, current and pulse output, alarm signal and RS-485 communication.

Product Using Conditons
– Ambient temperature: -10~60;
– Relative humidity: ≤85%RH;
– Atmospheric pressure: 86KPa~106KPa;
– Applicable Fluid: electrically conducting liquid;
– Fluid temperature:-25~ +65 and -25~ +140;
– Electrical conductivity: 5us/cm.

Technical Parameres
– Size: DN10~DN500;
– Standard pressure: PN1.0MPa~40MPa;
– Accuracy: ±0.5%~±1.0%;
– Supply power: 85 to 250VAC (45 to 63Hz), 16 to 36VDC;
– Signal output: Current Output: 0~10mA or 4~20mA;
– Frequency Output: 0~5000Hz with photoelectric isolation;
– Pulse Output: 0.001~1.000m3/cp, 0.001~1.000 Ltr/cp, 0.001~1.000USG/cp,
0.001~1.000 UKG/cp;
– Alarm Output: Upper Alarm-ALMH, Lower Alarm-ALML with photoelectric isolation;
– Communications: RS-232 without galvanic isolation, RS-485 with Galvanic isolation.

Item Compact type Remote type
Flange connection Inserted type Threaded connection Flange connection Inserted type Threaded connection
Caliber(mm) 15~3000 125~3000 10~25 15~3000 125~3000 10~25
Pressure(MPa) 0.6,1.0,1.6,4.0
Accuracy ±0.5%, ±0.3%(±0.2% available for special order)
Applicable medium Conductive liquid and slurry
Medium Temperature ≤150°C
Medium Conductivity ≥5μS/cm
Medium Velocity ≤15 m/s
Ambient Temperature:-25°C~+60°C, Humidity: 5%~90%
Liner Material DN10mm~32mm: Polytetrafluoroethylene(F4), Polyurethane;
DN40mm~1000mm: F4, Polyurethane, Polychloropree rubber;
DN1000mm~3000mm: Polychloropree rubber;
Others: Polyvinyl fluoride, Fluorinated ethylene-propylene(FEP), etc.
Electrode Material Mo-containing stainless steel, Hastelloy B, Hastelloy C, Titanium alloy, Tantalum alloy, Platinum-iridium alloy, Stainless steel-coated tungsten carbide
Electrode Type Fixed type(DN150~DN2600); Blade type(DN300~DN1600)
Flange Material SS, CS
Communication RS485, RS232, HART, Modbus, Profibus-DP
Signal Output Analog 4-20mA, isolated, load resistor≤750Ω
Power Supply AC 85-265V, 45-63Hz, power≤20W;
DC 11-40V; lithium battery(3.6V)
AC 85-265V, 45-63Hz, power≤20W;
DC 11-40V
Display LCD display with back light. Intelligent flow totalizer display.
Protection Grade IP65 IP65, IP67, IP68
Explosion-
proof Grade
ExdmIICT4, mdIIBT4 non